Telecom infrastructure

Telecom Towers

Why is a cell tower the application to watch? India has roughly 700,000 to 800,000 telecom towers, each drawing a few kilowatts around the clock, with diesel as the backup. Reliance's network has 200,000 suitable towers.

4.93M towers worldwide Grid · solar · diesel one unit
Talk to us about a site See the site run
12:00
a fixed isometric view · nothing moves but the current
Illustrative cycle, not measured site data.

One unit sits between every source and the load

The schematic from /applications/towers/, lifted into an isometric projection so the four sources read as four objects in one place. Fixed camera, fixed frame.

The sources this site has

12:00

Tower online · sources feeding it 4 of 4

Illustrative cycle, not measured site data. Schematic, not a wiring diagram: it shows where the unit sits relative to each source and to the load.

Four sources, one unit, and the tower it feeds. The parts are grouped, not placed where they stand on a real site. Current moves only on the runs that are carrying.

The problem

Power is the hard part of a tower

Radios, cooling and backup all draw continuously, and the site is frequently sited for coverage rather than for access to reliable power. Three constraints show up on almost every deployment.

Towers are power hungry

A tower draws a few kilowatts, around the clock, and its radios need power every minute of the day, whichever source is carrying the load.

Diesel is a running cost

On a weak grid the generator runs for hours every day, and fuel and generator service become part of the running cost of the site. Every hour solar carries is an hour the generator doesn't.

Off-grid generation is challenging

Where there is no grid at all, the site has to make and manage its own power. That is where diesel most often fills the gap, and where a PV inverter has to do more than feed a healthy grid.

Fewer units on site

The Quad optimizes four PV modules with a single microinverter. One unit per four panels instead of one per panel means fewer devices to install, commission and revisit.

Independent tracking per panel

Four DC input channels, each with its own peak-power tracking. A shaded or soiled module is held to itself rather than pulling its neighbours down.

Lose four panels, not the array

A central inverter fault takes the whole array offline. One Quad failing doesn't take down the rest of the array.

ACHV DC

All-AC output

Conversion happens at the array. What runs down the structure is AC, with no high-voltage DC string on a tower nobody visits weekly.

Panel-level DC stays low, roughly 40 to 60 volts per module, against the 400 to 700 volts a string inverter can put on the same roof, depending on string length. There is no string here, so there is no string voltage to manage.

Built for the long horizon

No failure-prone electrolytic capacitors; long-life components matched to the 25-year design life of PV panels. The temperature, enclosure, efficiency and warranty ratings a tower site specifies are in the table below, each with its source.

See the ratings

Shade, panel by panel

Against a string inverter the Quad wins on shade. Against a one-per-panel microinverter, per-panel shade performance is a tie, both track every module. The Quad's advantage there is unit count and installed cost, not harvest.

Explore the shade simulator

Telecom towers

The addressable picture

Millions of towers, most of them running on diesel for part of every day.

4.93M
Telecom towers worldwide
700–800K
India
~200K
Reliance suitable towers
The differentiator

One unit sits between every source and the load

Sparq's inverter runs on the grid, off the grid and alongside a diesel generator, and moves between them as a tower's power changes. That is what makes it a fit for telecom towers.

When the grid goes down, the inverter does not simply shut off. It can make its own AC power from the solar panels and keep the tower's critical equipment running through the outage. While the sun is up, solar carries the load without a battery; storage covers the night.

In Jio's installation demonstration, the switch from grid power to off-grid power takes about five seconds.

Gridutility supply presentSolar PVfour modules per unitBattery storageDC-coupled batteryDiesel generatorwhen the grid is absentSparq Quadone inverter, all-AC outputswitches between sourcesone lineRectifiersAC to DCBatteryon the DC busTower loadcontinuous, a few kW
The ratings, in one place

What a tower site actually specifies

The ratings a site engineer asks for, from our Quad2 datasheets. Off-grid and generator operation is the dual-mode (DM) edition, the one a tower site uses. The full table is on the Quad2 page.

At a tower siteQuad2 · Q2000-4102Source
The array
Modules per unit4, each on its own peak-power trackingDatasheet, both editions, Sep 23 2025DM datasheetGT datasheet
DC input power2000 WDatasheet, both editionsDM datasheetGT datasheet
Module rating per channel (STC)up to 680 WpDatasheet, both editionsDM datasheetGT datasheet
Maximum input DC current16 A per channelDatasheet, both editionsDM datasheetGT datasheet
The site
Grid connection208 V L-L from 3-phase · 240 V L-L from split-phase · 230 V L-N from single-phaseDatasheet, both editionsDM datasheetGT datasheet
Maximum continuous output2000 W at 52 °C (208 V) · 2000 W at 60 °C (240 V and 230 V)Datasheet, both editionsDM datasheetGT datasheet
Off-grid AC output90–245 V, 55 Hz nominal, 54–56 Hz range dual-mode edition onlyDatasheet Q2000-4102 DM, Sep 23 2025. The grid-tied edition carries no off-grid sectionDM datasheet
Switchover on loss of gridabout 5 seconds before the load is carried off-grid, as demonstratedJio's own installation demonstration, JIOSPARQ install video 8:22–8:44. Not a datasheet figure; a demonstration, not a ratingWatch it at 8:22
Efficiency
Maximum efficiency97.5 %Datasheet, both editions; also the July 2022 v1.0 manual, p. 51DM datasheetGT datasheetManual v1.0, p. 51
CEC efficiency97 %Datasheet, both editions; also the July 2022 v1.0 manual, p. 51DM datasheetGT datasheetManual v1.0, p. 51
MPPT efficiency99.85 % static · 99.8 % dynamicDatasheet, both editions; also the July 2022 v1.0 manual, p. 51DM datasheetGT datasheetManual v1.0, p. 51
Standby consumption< 30 mWDatasheet, both editionsDM datasheetGT datasheet
A structure nobody visits weekly
Enclosure ratingNEMA 6, IP-67Datasheet, both editionsDM datasheetGT datasheet
Ambient operating temperature−40 to +65 °C (−40 to +149 °F)Datasheet, both editionsDM datasheetGT datasheet
Relative humidity0–100 %, condensingDatasheet, both editionsDM datasheetGT datasheet
Weight3.3 kg (7.3 lb)Datasheet, both editionsDM datasheetGT datasheet
Coolingnatural convection, no fansDatasheet, both editionsDM datasheetGT datasheet
Standard limited warranty12 yearsDatasheet Q2000-4102, both editions, Sep 23 2025DM datasheetGT datasheet
Extended warrantyUp to 25 years on both grid-tied and dual-mode editions, subject to the extended-warranty termsConfirmed by Sparq, October 20, 2026Request warranty terms
Design life25 years. Design life is not a warranty termDatasheet Q2000-4102, both editions, Sep 23 2025DM datasheetGT datasheet
Grid interconnection
Certifications listed for IndiaBIS IS 16221 (Part 2) · BIS IS 16169Quad2 datasheets, both editions, Sep 23 2025DM datasheetGT datasheetFull certification list
Protectionprogrammable anti-islanding · integrated GFDI · galvanic isolation · abnormal voltage or frequency trip in under 200 msDatasheet, both editionsDM datasheetGT datasheet
Telecom towers

Bring us onsite

Tell us your tower's load, how reliable the grid is, and how long the generator runs. We'll tell you what the Quad can do at that site.

Talk to us Drive the site again Quad2 in detail
Get a quote